Air mapping is a process of collecting a series of readings using the GrayWolf Advanced Sense Pro.

General Information

This instrument can analyze the ambient air within a
space/room/area for the following:

  • TVOC
  • Temperature
  • Relative Humidity
  • Carbon Monoxide
  • Carbon Dioxide
  • Oxygen
  • Ozone
  • Particle Counter (0.3, 0.5, 1.0, 2.5, 5.0, and 10 µg/m³)
  • Ammonia
  • Sulfur Dioxide
  • Hydrogen Sulfide
  • Formaldehyde

When To Test


Normally,air mapping readings is used to “map” the building for spikes and anomalies
to determining potential locations for collecting 
Volatile Organic Compound (VOC) Air
Samples.
If there is a known chemical odor or recent installed material that may be emitting toxic
fumes, this product may be used on a project.
We often receive inquiries about particulate count services during our California wildfire
season. While we certainly can perform this testing if wanted, during that season,
normally the most prudent approach is to close all doors and windows and utilize HEPA
air purification machines to adequately address the square footage of the indoor space.

Our Process

Prior our arrival on-site, we would discuss a series of situations and ask certain
questions to determine if this type of service might be appropriate for a particular job.

How We Test

The procedure for air mapping involves collecting a series of readings over a specified
period of time, per location. This allows us to accurately assess the area with more than
one reading.
If any spikes or anomalies are detected, we may recommend further VOC air sampling
in specific locations.

Interpreting Results

All readings would be compared in the first instance to subsequent readings of the
same room or space. These readings would also need to be compared to any
applicable EPA permissible exposure limits (PELs) that have been established.

Cleanup Action

If an elevation of a specific contaminant is found through this testing, then an abatement
protocol can be developed. The abatement action may be as simple as removing the
source (i.e. paint cans in a garage) or can be more in-depth if there has been an
application of material onto the building material substrate (i.e. paint applied on walls).
That would involve either removal or further action, specifically “structural-pasteurization
” through the use of heat treatment.

The process of structural pasteurization can be used to help volatilize odors under
negative pressure using engineering controls. This interior heat treatment increases the
temperature of a structure with the goal of reducing targeted chemical(s) that are
referenced in the air mapping readings or VOC air sample results. This heat abatement
process usually takes between 2 to 5 days depending on the severity of the chemical
off-gassing and the square and cubic footage of coverage area. This typically includes
air filtration, temperature control and monitoring, and air pressure control which will
provide appropriate air and temperature distribution to the structure. The temperature in
the structure is elevated to 105ᴼ-120ᴼF, increasing the vapor pressure of the various
volatile chemicals to speed up the process of off-gassing. This off-gassing is then
exhausted outside of the building using large HEPA air purification machines. Air
filtration will use HEPA filters to capture much of the particulate and may also use
carbon filters to capture vapors. In many situations the structure, or portions of the
structure, may be heated under negative pressure, allowing both ultrafine and fine
particulate to be exhausted along with the target vapors.

There is always a chance that any wood trim, wood floors,or other decorative wood
components can become damaged during this process. This should be discussed with
the abatement contractor to make sure safeguards are in place with careful monitoring.
All furniture should be removed.

Post Abatement Validation Testing

After abatement is complete, we can return for post-treatment validation testing to prove
that levels have decreased.